Model Number |
sk-500II |
Function introduction Sk-500II syringe pump Function features 1: Three kinds of modes: Rate Mode, Time Modes, Body Weight Mode. 2: Accept all standard syringes of 5ml, 10ml, 20ml, 30ml and 50ml. It will self- diagnose and display the syringes size and the set parameter automatically in the form of menu. 3: Unique syringe supervision system ensures the patient's safer and less the nurse's workload. 4: Excellent syringe operation. The accuracy will be ensured even at the small-quantity infusion 5: Double CPU supervision makes the process of infusion safer and more reliable. 6: Precision step motor. There is no pulsating wave even during low speed infusion 7: Accurate and sensitive pressure sensor directly examines occlusion pressure accurately. 8 Alarm when there is malfunction or operation error, and the machine stops running automatically. 9: KVO rate can be selectable according to concrete requirements from 0.1ml/h to 5ml/h. 10: Save the preset volume automatically when there is unpredictable switch off, ensuring the accuracy of infusion volume. 11: Can check the infusion time, dose, solution during the process of infusion. Technical parameters 1. Dimension: 288?30?22mm 2. Weight: 3.0kg 3. Power supply: 50/60Hz AC100V~240V 4. Display information 1.) Flow rate 2.) Accumulated syringe volume 3.) Preset volume 4.) Syringe size 5.) Pressure value 6.) Syringe specification 7.) Battery capacity 8.) Unit of medical dosage 9.) AC power indicator 10) Bed number 11.) Pressure Value 5. Fuse: 220V2A?, 12V2A? 6. Max power consume; 25VA, 5h after being recharged 7. Syringe increment: 0.1ml 8. Accumulated injection volume: 0~9999.9ml 9. Syringe accuracy: ±3% 10. Alarm function (can be transmitted to the infusion supervision system at the nurses?station. ) 1.) End of infusion 2.) Near end of infusion 3.) Occlusion 4.) Low battery 5.) Disengaged 6.) Injector abnormal 7.) Control abnormal 8.) Internal malfunction 11. Electromagnetic compatibility: Complies with the stipulation of IEC60601-1-2(1993 edition) 12. Applicable syringe: Syringes meeting national standard: 5ml, 10ml, 20ml, 30ml, 50ml 13. Feasible syringe rate range 5ml syringe: 0.1~100ml/h 10ml syringe: 0.1~200ml/h 20ml syringe: 0.1~400ml/h 30ml syringe: 0.1~600ml/h 50ml syringe: 0.1~1500ml/h 14. Battery: Rechargeable lithium polymer battery, 7.4V, 1600mA 15. Bolus rate: 5ml: 100ml/h 10ml: 200ml/h 20ml: 400ml/h 30ml: 600ml/h 50ml: 1500ml/h 16. Occlusion value: 400mmHg~900mmHg 17. Selectable mode: Flow rate mode, Time mode, Weight mode 18. Time mode Liquid limit: 0.1~999.9ml 19. Weight mode 1.) Selectable unit: ml/h, mg/h, ug/h, mg/kg/h, mg/kg/min, ug/kg/h, ug/kg/min 2.) Medical limited: 0.1~9999.9(mg/ug) 3.) Liquid limit: 0.1~999.9ml 4.) Weight: 01~300.0kg 20. KVO rate:0.1ml/h~5.0ml/h 21. Environment condition: Environment temperature 5~45°C, air pressure 70~106kPa, relative humidity 30%~90% 22. Storage: Environment temperature -15~50°C, air pressure 70~106kPa, relative humidity 30%~90%
|